|









| |
 |
Dynamic Array -
The BioMark 48.48 Dynamic Array is the ideal solution for mid-multiplex genotyping, at very high sample throughput.
|
Research Challenge
Genetic
research usually begins with whole genome screens of a few samples with hybridization
arrays to develop candidate gene profiles. But, that’s often where the progress
stops. Many laboratories lack the resources to take the followup step—validation
of the 30 – 300 genes uncovered in screening against a sufficiently large
population. SNP genotyping by PCR is the most rigorous approach to validation;
however, performed in microwell plates, genotyping is entirely too arduous in
terms of material- and liquid-handling complexity. This reality leaves many
good hypotheses waiting in the wings. |
|

The 48.48 Dynamic Array. Click image for details. |
The Solution
The BioMark 48.48 Dynamic Array is a highly efficient solution for mid-multiplex genotyping (projects that involve between 30 – 300 genes) using TaqMan® PCR assays. The key to this efficiency is the matrix of channels, chambers, and valves that do the work of assembling assays. Forty-eight samples and 48 assays are loaded into the inlets of the chip’s input frame and pressure loaded into 2,304 reaction chambers. That’s a total of 96 steps to test 48 genes against 48 samples in a single run.
The savings in time and effort add up rapidly. For example, a 2,000-sample study could be completed with only 4,032 pipetting steps. That’s just two percent of the 192,000 steps that would be required to complete the same study with microwell plates. With dynamic arrays, genetic researchers can advance their research much more easily and affordably, and they can do so while using gold-standard TaqMan® assays.
The 48.48 Genotyping Chip at a Glance
Parameter |
Specification |
| |
Assay
transfer rate* |
98.00 % |
|
Call
accuracy |
99.75 % |
|
Call
rate |
99.00 % |
|
Chip
footprint |
128 mm
x 85 mm x 14 mm |
|
Inlet
spacing on input frame |
4.5 mm
pitch |
|
Liquid-transfer
steps |
96 |
|
Primer-probe
inlets |
48 |
|
Sample
inlets |
48 |
|
Reaction
chambers |
2,304
(48 x 48) |
|
Chip
loading |
Nanoflex™
4-IFC Controller |
|
Detection
and analysis |
BioMark™
Real-Time PCR System |
|
| |
*Percent of licensed PCR assays that yield 99.75 % accuracy on BioMark dynamic arrays.
TaqMan is a registered trademark of Roche Molecular Systems, Inc.
© Fluidigm Corporation. All rights reserved.
Fluidigm Corporation | 7000 Shoreline Court, Suite 100 | South San Francisco, CA 94080
Phone:(650)266-6000 Fax:(650)871-7152
Limited License
|  |
|